We recommend placing a ball-valve at the top of the flex line so you can isolate the pump if need be. The dry vent goes up to the vent stack and the wet vent goes down to the main drain line for the room. Installing a Saniflo system isn't difficult! If you havent, its not hard to find one you love. Using a series of PVC connections, connect the macerator pump to your homes vent system. All Amazon markings and logos are the exclusive trademarks and property of Amazon.com, Inc., or its affiliates or subsidiaries. A Venting System. Keep in mind the SaniCompact and SaniStar do not require ventilation. Saniflo offers a wide range of macerating and grinding pump systems as well as drain and condensate pumps. Connect it to a power source and ensure it runs as desired. If your unit has a hole at the top, plug it with the clear plastic stopper that comes with it. The SaniACCESS, SaniPLUS, and SaniBEST Pro are our best-selling models and the easiest ones to install. Step 1: Determine the Best Location of the Vent, Tips for Effectively Venting a Saniflo Upflush Toilet. Start by cutting a hole in the wall near the Saniflo upflush toilet. However, a vertical venting system is ideal for toilets on the upper floors. Hi, I just bought a Saniflo SaniAccess3 upflush toilet for my basement and after reading the instructions and doing some research on the internet, I'm still unclear on how to vent it. You must log in or register to reply here. Installing a basement bathroom can improve your homes value. This allows gravity to do its part after the pump has done its part. These systems must also be vented in the same manner as traditional drain lines. Venting your toilet depends on various aspects including the size of the pipes, the design of the toilet and the regulations in your area. Depending on the pump model, the discharge pipe can be 3/4 or 1 inch diameter pipe. DoItYourself.com, founded in 1995, is the leading independent To achieve this, slice the stack with a hacksaw and put both extremities into the big fitting slots. The best way to vent a toilet sink and shower is to use wet venting which is the method explained in the sections above. In this guide, were going to provide a simple step-by-step template for installing your new upflush system. Run the vent to the main stack. Ideally, it should not be higher than the uppermost floor with a kitchen sink or toilet. All plumbing codes require connection to a vent system. For l. The motor is filled with oil and sealed for life at the factory; draining the oil out of the motor voids warranty as well. This is an added bonus of the installation of Saniflo. The extension pipe is designed to be used with the Sanitop, Saniaccess3, Saniplus, Sanipro and Sanibest Pro models. Gather all Your Equipment You won't need much to install your new system. As an Amazon Associate, we may earn an affliate commission whenever you purchase through links on our pages. Install a 4-inch to the 1-1/2-inch reduce T-fitting on the vent-and-soil stack. The venting hose should be made of a flexible material so it can easily route to the desired location. If youre unsure where the vent pipe is, you can always ask a plumber or look for it yourself. You should have chosen this model by now. Turn on your Saniflo system and allow it to run for a few minutes so that any air bubbles can be purged from the lines. With Saniflo above-floor plumbing technology, you decide where your new bathroom, kitchen or laundry room goes! Ensure the discharge line gets pitched correctly so the water will flow properly and not cause any backups. If you want to hide the pipes, you can frame a lower ceiling to do so. You can only increase the pipe size when you start draining the waste through gravity since the 1/4" per foot will drain the waste. Yes. Install the included discharge elbow and set the discharge piping. The PVC pipe should stretch between the wall studs to the attic. This small vent hole is not used in the United States. This is because the UPC requires that there be a vent pipe in the home which is at least the same size to the sewer pipe. The next step in your install is to tap into a fresh water supply. Insulate the pipes by wrapping them in foam pipe insulation. When the toilet is flushed, the water level rises, and the macerator grinder pump motor turns on automatically. Switch off the macerator again and allow the descaler to work for 2 hours. Another option is to link the drain pipe of the Saniflo upflush toilet in the basement to an established vent system for fittings such as floor drains, laundry, or a bathroom vent stack on a higher floor. The concrete floor must be broken into and drainpipes installed, then new concrete must be poured. However, these gases need to be released since without a vent the toilet becomes a closed system. Its significantly more green when compared to older-style commodes that may use up to 3.5 gallons (30 liters) of water per flush. Since the Sanicompact 48 and Sanistar versions are self-contained, they do not need a vent connection. If you need to make a 90 degree turn you can accomplish this with two 45-degree turns. It has two sides, a stretchy side, and a stiff side. All of those with the exception of the SaniShower can handle a bathtub. Instead of using gravity to drain, an upflushing toilet has a heavy-duty pump activated by a float and switch. Just follow these simple steps to ensure the process of installation is streamlined and smooth: 1. We recommend the discharge pipe pumps up vertically as high as necessary from the start point, then maintain a slope per linear foot until it enters your sewage line. However, we recommend the use Saniflo's Descaler which acts as a cleanser and descaler. Level in both directions. Also, dont connect the upflush vent to the vent-and-soil stack below the lowest wastewater drain connection. Just like the drain line or waste line in your home, an upflush toilet should vent into the houses main vent stack, which often extends from the main sewer line up through the roof. If access to the houses vent system isnt possible, the vent pipe can run along the beams outside the house. Once youve located the vent pipe, its time to attach the venting hose. To better understand the system, check out this short, 2-minute video: Installing a Saniflo system isnt difficult! Toilets come with very simple mechanisms including a P-trap and a venting mechanism. 2. Venting a basement bathroom can be a challenging process. The discharge pipe must be set up to pump straight up vertically to the highest point and then horizontal with a slope of at least 1/4 inch per linear foot into the main drain pipe. It will prevent the pipes from freezing and avoid any damage that frozen pipes could cause. If you have a question, want to register your product or need to find a Saniflo installer, we are here to help! A: The size of the discharge pipe on a Saniflo pump depends on the pump model. Each home has them in different places. How to Install a Saniflo Toilet Family Handyman 137K subscribers Subscribe 857 Share Save 121K views 1 year ago #familyhandyman #diy #howto Want a toilet in your basement, but don't want to. Venting is crucial because it prevents the system from being overwhelmed by too much water. For typical usage, Saniflo macerators require descaling twice a year. Connect the other end of the vent pipe to the city sewage system. This will keep odors from coming into your living space. The end with the inner gasket built inside attaches to the back of the toilet (no need for a clamp on that end) and the other end of the extension pipe is clamped to the front of the unit; inside the pan gasket. Next, youll need to install the macerator. Why Is Venting Important? In addition, this exercise curbs gurgling noises and helps keep your household safe from inhaling methane gas, which is hazardous to your health. Make sure the vent and drain conform to local plumbing codes. Install horizontal PVC plumbing to the vent-and-soil stack and a 90-degree PVC corner fitting on the attic upflush vent pipe. We'll also add a few customer photos of a successful installation. All information is provided "AS IS." All rights reserved. Install the supply line. Given that drain pipes need to be slopped between 1/8 and of an inch per foot of horizontal travel, you should calculate the amount of vertical space available on the flow then use that to lay the pipes and other fittings. Know the plumbing codes of your area or get a plumber to help you become familiar with them. Macerator or Grinder installation are quick and easy to install. The outlet of the tee should point upwards and be perpendicular to the drain pipe. All fixtures connected to the Saniflo system must sit on the same level. This is simply an add on to your existing plumbing. A pump drives wastewater up a tiny pipe into the city sewage system. Important tips for the correct installation of a Saniflo Sanibest Pro Full Bathroom Grinder. To exercise your rights, contact SFA at the following address: 41 bis avenue Bosque 75007 Paris or on the contact section of this site (by justifying your identity). This can easily mess up the toilet. Locate the uppermost wastewater drain link on the vent-and-soil stack and connect it to the vent pipe on the Saniflo upflush toilet, preferably in the attic. The Saniflo pump is electrically-operated, which means youll need access to a 15-AMP circuit to power it. Upflush toilets are the way forward when it comes to home plumbing. If youre not installing any other fixtures on your system, replace the inlet blanking plug and be sure its seated properly. Just gather the following things before you begin: Your Saniflo Upflush Toilet. It can handle the effluent from a toilet and sink in a residential application. Upflush systems need bi-directional air movement so that air moves out after flushing the toilet and moves in when pumping water into the system. Use clamps or other fastening devices to secure the hose to the ceiling, floor, or walls. However, if your basement ceiling is too hard to make holes or you dont want the risk of holes in your basement ceiling floor, consider installing a wall fan, which is a better alternative. 1. Can a clogged vent cause a toilet to overflow? The venting system of your toilet is based on how liquids and gases work in terms of their weight and response to behavior. All of Saniflo products are designed to pump out the waste into a city sewer, septic tank or soil stack. Also, you cannot overload a vent stack. Install the subfloor and walls, being careful not to puncture the tank with any fasteners. Enable registration in settings - general, How to Run Water Line to Fridge on Opposite Side of Sink. how has it worked out? To install the fan, make holes with a drill machine in the ceiling and securely fix the fan. However, weve found out that lot of these pieces of equipment are in use all around the country and the chances of it being illegal in your area is very low. This toilet uses blades to grind up solids for easier pumping. Ensure the vent connection installed on top of the tank matches the fittings and the diameter of the PVC pipes. However, if roughed-in plumbing hookups are not in place, installing traditional plumbing can be both expensive and laborious. There are essentially two types of venting options. Make sure it is above the highest waterline, as stated, and then using a piping cutter, cut a 4" piece of Schedule 30 PVC pipe and then push it through the hole in the wall. If this is a concern for you, insulate the pipes. You can do it for toilets installed on the upper floors and those in the basement. You can vent your Saniflo system anywhere, providing it meets the following requirements: air moves in and out and it adheres to local codes. How and where to install an air admittance valve. The installation of a Saniflo unit is simple and straightforward and can be completed, from start to finish, in about six to eight hours. Upflush systems need bi-directional air movement so that air moves out after flushing the toilet and moves in when pumping water into the system. When venting Saniflo upflush toilets, avoid using cheater vents or AAVs because they will create airlocks and cause sewer gases to waft into your house. The only exception is the SaniBEST Pro. View our Privacy Policy here. Flush the toilet and make sure that the waste is properly discharged. This post will teach you how to vent a basement bathroom and offer a simple diagram to get you started. Be sure to configure the vent and drain in a code-approved manner. All models in the Saniflo line are low consumption. Pipe freezing can happen. Ensure the venting hose is made of a flexible material so it can easily route to the desired location. Urine is emptied from the bowl and into the main waste line by urethane-coated polypropylene. When you flush waste, it moves from the bowl to the macerator. Secure the pump and toilet to the floor (you already installed the rubber feet, right?). It allows the toilet to run long enough to break down waste materials effectively. Can I see some photos so that I can see what this might look like? Carry hand sanitizer and disinfectant wipes in case facilities lack soap or running water. You should have chosen this model by now. Yes I did vent as I had said and it has been working flawlessly. From the invention of the first macerator 60 years ago right up the innovation happening today, find out more in this section about Saniflo and its parent company; Group SFA. 2. Saniflo upflush toilets need bi-directional venting to enhance airflow in both directions. The flush cycle normally takes 15 to 18 seconds. Ensure the room has proper ventilation to eliminate odors and moisture that could prove problematic later on. Can I discharge the waste by means of upward slopes? For further information, please consult our cookie and personal data policy: https://www.sfafr/content/17-cookies-personal-data. To clean your upflush toilet, pour 1-2.5 liters of non-acid Toilet Cleaner and Macerator Descaler into your toilet bowl. You can install the macerator pump into the vent system of your apartment. If you already have a sewer gas line in place, then connect the vent lines with the existing lines. You will need to use a clamp or other fastening device to secure the hose to the vent pipe. How To Use Shower Felt Pad in the Bathroom, Thinset for Shower Floor: What it Is and Why it Matters. In wet venting, the sink drained is connected to the toilet water line using a reducing sanitary tee. How to Vent a Basement Bathroom (With Diagrams), All products 15% off MSRP - No Sales Tax - Free Shipping. A 3-inch vent is required. In fact, most DIY installations take just a few hours to complete, and theyre typically faster if you hire a plumber to help you. Most manufacturers supply an extra flange for hooking up a tub/shower and sink drain to the tank. Another hinderance is a lack of venting. Saniflo does not sell directly to the public. Step 4 Attach a PVC collar fitting and then a PVC pipe, to the top of the tank's vent connection. Find a 1 & 1/2-inch fitting vent connection on top of the Saniflo upflush tank. You don't need custom equipment! Slowly fill the tank with water. For any turns, we recommend using two 45 degree elbows back to back or long sweeping elbows. Remove the lid of the Saniflo and check the inside of the return valve for anything that may be stuck - discard of it with small pliers. The shower base will need to be raised a minimum of 6 inches, but is recommended 8 inches. Once youve installed the venting hose, its time to test the system. Connect the System to Water Next, make it possible to flush your toilet by connecting the toilet tank to your water supply. For more information, heres an example of basement bathroom venting, with a diagram from Terry Love Plumbing: If you dont want to rely on the above diagram and dont feel comfortable completing the work yourself, you can always hire a plumber to help you vent the basement bathroom. The Sanicompact 48 and Sanistar models do not require a vent connection since they are considered self contained units. The Sanicubic range uses 1-1/2" diameter discharge pipe. What is Rough in Height for Urinal Drain. Just gather the following things before you begin: Your Saniflo Upflush Toilet. Newer units are more dependable. I had some generic questions regarding sewer venting and toilets. (Be sure to install it with the correct end upit is clearly marked.) Find an electric source complete with a GFI breaker to outfit your new system. However, tying in a vent line improperly can cause siphoning from other fixtures when the toilet is flushed. The vent should be located within 5 feet of the macerator, preferably close to the toilet. Yes. Before sealing the unit, make sure the pump works. In the event of a power loss, do not use the toilet or any sanitary fixture connected to the pump since it will not work until the power is restored. If necessary, build a simple 2x2-inch frame, mix and pour sand-mix hydraulic concrete, and set the unit in the concrete. This helps decrease the likelihood of blockages and backups and extends the lifespan of your system. The sweep of the reducing sanitary tee should be towards the flow of the water and the outlet of the tee is to point upwards. Regardless of the size of the house, venting a Saniflo Upflush toilet in your basement will improve healthy breathing in your home. If you have prerequisite knowledge and skills in plumbing, you can try a DIY. An upflushing unit has a heavy-duty pump activated by a float and switch. Nonetheless, other fixtures may require venting as per the local plumbing codes. It can prevent the system from working correctly. When the sanitary line is not nearby, installing a toilet or bathroom can be difficult, if not impossible. The macerator is a powerful tool complete with a sharp, rotating blade. Yes. Start by creating (drilling) a hole at the unit's top. Installation of Vent Pipes Use 4 inch PVC pipes joined with pipe cement for the drain vents. To help the pump work as well as possible, limit bends and elbows in your discharge pipe. A: Bad smell from your upflush toilet is often occasioned by the build-up of limescale and human waste in the 2 inches of water that is often left in the Saniflo bowl. The waste connection is made with a sanitary tee whose sweep is directed towards the sewer and then the vent pipe is glued to the port that would be facing upwards. I'm installing a Saniflo Saniaccess 3 upflush toilet, which also serves a shower drain and sink drain (full bath). An upflushing unit makes the job much easier. Upflush toilets are typically installed in retrofitted basements. When the lower portion of the tank fills, the pump turns on, forcing waste up through the 2-inch drain. A clogged vent can lead to an imbalance in the pressure of the toilet leading to an overflow. Therefore, the pump must breathe in and out for the system to work optimally. Its the best available, but sacrifices being quiet to do so. Luckily, were here to help. Although water and waste from upper floors flow into the vent-and-stack, the pipe also serves the purpose of the houses vent system. Besides, you will want to hide the ventilation pipes by lowering the basement ceiling. An Electricity Source. Sewer gases are hazardous to your health so proper drain venting is a very serious matter. For an upflush venting unit, locate and disconnect the venting systems wall connection from the wall. The plumbing vents terminate in the vent stacks at the roof of your building. It will help you troubleshoot effectively and prevent further issues. While most Saniflo units can use piping, it can be as large as 1. If you need to run a vent line outside of the building, it has to terminate above the roof line. Venting allows a balance of pressure between them to allow the wastes flow to the drain and the gases to escape to the outdoors through the vent. You only need four basic connections: A top rated SaniFlo upflush toilet pump system A supply of water A small discharge pipe (3/4 to 1") A source of electricity with a GFI breaker. The pipe also functions as a vent to the drainage system and is sometimes referred to as a vent-and-soil stack. But if you want to DIY, then we hope these steps we have mentioned above can come in handy. When the lower portion of the tank fills, the pump turns on, forcing waste up through the 2-inch drain. Plug the unit into a GFCI receptacle. SFA offers you easy and reliable solutions for any job! It prevents airlock and putrid sewer gases from wafting into your house, making your toilet function properly. While running water would point to a leak in the toilet tank, air bubbles coming into the toilet bowl would indicate poor venting. Also, it is not recommended to use an air admittance valve or a mechanical spring-loaded device as they allow air to flow in one direction. Follow this up by connecting the left and right parts of the tee pipe with the sewer pipe and then positioning the disconnected pipe to the ceiling. Keep in mind you cannot have the discharge line make any hard 90 degree turns. It works for those who dont want to spend thousands of dollars on extra plumbing. There are many different ways to run the plumbing vent lines. 1 1/2-inch PVC vent piping and 2 . If the distance from the fixture to the vent stack is too great, the fixture will not drain properly. This is certainly the 1-1/2-inch fitting on the upflush tank. Lay the vent and drain pipes before the supply pipes to get the best results. Saniflo recommends to use PVC, CPVC, copper. My basement bathroom build video I install a Saniflo up flush macerating Toilet 4 of 4Thank you very much for watching and God bless.Video 1 bathroom build. The biggest perk of a Saniflo installation is that you can vent the toilet anywhere. You can do this by cutting the stack pipe with a hack saw, then inserting both ends of the stack into the large fitting opening. Tape the temporary drainpipe jointsthe pump is forceful. 3. Smarter, faster, cleaner, Saniflo makes it simple! Limit time spent in a public washroom in a single visit (less than 15 minutes). The blades driven by the motor, macerates/grinds the contents into tiny particles in 3 or 4 seconds. Connect a 2-inch PVC drainpipe to the discharge unit and run it toward the house's drain in a code-approved manner. She is a writer and editor with nearly a decade of interior design expertise. They build up in the 23 inches of water often left lingering in the Saniflo. Install the subfloor and walls, being careful not to puncture the tank with any fasteners. Your discharge pipes can be small between and 1, so you have some room to play with sizes and find one that works for you. Currently, the building code in most municipalities requires not just a drain in the basement floor but a bathroom to be vented with the use of an operable window or an exhaust fan.

Difference Between Hinduism, Buddhism, Islam And Christianity, Mouton Plantation Slaves, Articles H

how to vent a saniflo upflush toilet